Item specifics
Flow capacity2.5 ~ 95 m3/min
Pressure dew point-40 ℃
Working Pressure4~10barg
Max. inlet temperature50 ℃
Max. ambient temperature45 ℃
Power supply220V/1Ph/50/60Hz

Heatless Regeneration Compressed Air Dryer

Description

SCALA XH series Heatless Adsorption Dryers are simple and reliable method to remove moisture and impurities from compressed air. The outlet pressure dew point from -40 °C to as low as -70 °C.  Compressed air flows alternately through twin towers filled with desiccant,It provide continuous dry air and regenerating the desiccant media through it's dry air, minimal maintenance is required.


Features and Benefits

High Performance Valves

Time proven stainless steel pneumatic angle seat valves have five years service interval. High performance butterfly valves have three year service interval. Externally mounted solenoid valves for easy functional testing and troubleshooting.


High performance Desiccant

High strength activated alumina filled into adsorption towers to ensure stable pressure dew point. Double fixed bed layers, respectively filled activated alumina and molecular sieve for pressure dew point of -70℃.


Advanced PLC controller

SIEMENS LC Controlling system executes and monitors all dryer functions. 7 inch touch screen panel displays dryer status and related alarms. Modbus/RS-485 port and remote on/off and alarm alarm function.


Optional Mounted Filter Packages

For space saving and quick installation, high performance pre-filter with automatic drain  and after-filters available.


Optional Dew Point Control

When you chose a dryer with dew point display. Dew Point Control can extended the switch cycle and compressed air consumption


Technical Data

Model

Flow Rate

Inlet/Outlet Connection

Dimensions

Weight

m3/min

CFM

Lmm

W mm

H mm

kg

XH38

3.8

134

G1”

830

570

1600

175

XH65

6.5

229

G1-1/2”

1020

610

1710

310

XH100

10.5

371

G2”

1160

680

1900

430

XH130

13.5

476

G2”

1160

680

2200

522

XH170

17

600

G2”

1200

690

2160

580

XH210

21.5

759

G2-1/2”

1280

980

2310

720

XH250

25

883

DN65

1350

930

2450

820

XH280

28.5

1006

DN80

1460

1060

2320

1000

XH320

32

1130

DN80

1460

1060

2510

1100

XH370

37

1306

DN80

1580

1080

2460

1250

XH400

41.5

1465

DN100

1700

1160

2730

1350

XH450

45

1589

DN100

1765

1160

2550

1420

XH500

50

1765

DN100

1765

1160

2750

1550

XH550

55

1941

DN100

1825

1150

2690

1640

XH600

60

2118

DN100

1825

1150

2790

1790

XH650

65

2294

DN125

2040

1240

2820

2000

XH700

70

2471

DN125

2040

1240

2920

2120

XH750

75

2648

DN125

2040

1240

3120

2220

XH850

85

3000

DN125

2210

1350

2970

2420

Note: Flow capacity is base on 7bargs of inlet pressureof inlet temperature

Correction Factors

Actual Capacity (m³/min) = Nominal Capacity × KA × KB

Working Pressure (KA)

Barg

5

6

7

8

9

100

psig

73

87

100

116

131

145

CFP

0.87

0.94

1.00

1.06

1.12

1.17

 

Inlet Temperature (KB)

35

38

40

42

45

50

95

100

104

108

113

122

CFT

1.18

1.00

0.90

0.81

0.69

0.58