Small heatless desiccant compressed air dryer for CNC machine
- Price
- US $500
- Model
- XM0060
- MOQ
- 1 piece
Item specifics
- Normal flow rate
- 36 m3/h
- Max operating pressure
- 10barg
- Pressure dew point
- - 40 to -70 deg c
- Inlet/outlet connection
- 1/2''
- Voltages
- 230V, 50/60Hz
- Power Consumption
- 30W
- Weight
- 23kg
Review
Description
XM Series Mihi heatless desiccant compressed air dryers are designed for continuous separation of water vapour from compressed air thus reducing dew point. Operation of dryer requires two columns operated alternately.
Adsorption takes place under pressure in first column while second column regenerates with a portion of already dried compressed air at ambient pressure.
A dryer consists of two columns, filled with desiccant beads, controller with LCD dicplay, valves, manometers, support construction and suitable filter housings with the required filter element. Proven robust design enables efficient and reliable operation, fast installation and simple maintenance.
√ Compact & robust aluminum-alloy structure
√ Pressure dew point of -40℃ as standard, optional -70℃
√ Two stage per-filters and outlet dust filtersto ensure clean air
√ Low dust adsorbent with longer serviceperiod and less filling quantity
√ Bufferchambers in upper and lower end to reduce pressure drop
√ Intelligentcontrol with automatic working after powering on
√ Very low purge noise due to gas cylinder structure
TECHNICAL DATA | |||||||
Connection | Nominal volume flow | Dimensions | Weight | ||||
Type | IN/OUT | [Nm3/h] | [CFM] | L[mm] | W[mm] | H [mm] | kg |
XM0005 | G 1/4'' | 3 | 1.8 | 190 | 125 | 600 | 6.8 |
XM0010 | G 1/4'' | 6 | 3.5 | 190 | 125 | 700 | 8 |
XM0015 | G 1/4'' | 9 | 5.3 | 190 | 125 | 830 | 9.8 |
XM0028 | G 1/4'' | 16.8 | 12.7 | 190 | 290 | 1000 | 11.8 |
XM0060 | G 1/2'' | 37.2 | 21.9 | 330 | 290 | 710 | 23 |
XM0100 | G 1/2'' | 60 | 35.3 | 330 | 290 | 850 | 25 |
XM0130 | G 1/2'' | 79.2 | 46.6 | 330 | 290 | 1020 | 30 |
XM0180 | G 1/2'' | 108 | 63.5 | 400 | 380 | 1020 | 38 |
XM0240 | G 1'' | 147 | 86.5 | 505 | 505 | 1175 | 54 |
XM0360 | G 1'' | 220 | 129.9 | 645 | 645 | 1175 | 72 |
Refers to 1bar(a) and 20°C at 7 bar operating pressure, inlet temperature 35°C and pressure dew point at outlet -40°C.
CORRECTION FACTORS - F1 | |||||||||||||||
Operating pressure [bar] | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Operating pressure [psi] | 29 | 44 | 58 | 72 | 87 | 100 | 115 | 130 | 145 | 160 | 174 | 189 | 203 | 218 | 232 |
Correction factor | 0.38 | 0.5 | 0.63 | 0.75 | 0.88 | 1 | 1.13 | 1.25 | 1.38 | 1.5 | 1.63 | 1.75 | 1.88 | 2 | 2.13 |
CORRECTION FACTORS - F2 | |||||||||||||||
Inlet temperature [°C] | 25 | 30 | 35 | 40 | 45 | 50 | |||||||||
Correction factor | 1 | 1 | 1 | 0.97 | 0.87 | 0.8 | |||||||||
DEW POINT FACTORS- F3 | |||||||||||||||
[°C] | -25 | -40 | -70 | ||||||||||||
CD | 1.1 | 1 | 0.7 |