46CFM refrigerated air dryer shows excellent pressure dew point
- Share
- publisher
- Sean Wu
- Issue Time
- Feb 25,2017
Summary
We tested one unit of SCD78 refrigerated air dryer from production line the pressure dew point is +6 deg c under inlet 38 deg c ;and 2-3 deg c under inlet 35 deg c, pressure drop is less than 0.2bar.

Feb. 23, 2017
We tested one unit of SCD078 refrigerated air dryer from production line,the dryer has rated flow capacity of 1.3m3/min (46cfm) based on standard inlet temperature of 35 deg c, at 7barg, +3 deg c dew point.
After testing by compressed air, the pressure dew point is +6 deg c under inlet 38 deg c ;and 2-3 deg c under inlet 35 deg c, pressure drop is less than 0.2bar.
SCD78 is adopted with high efficiency 3-in-1 stainless steel heat ex-changer and precise hot gas bypass valve,for customer's long term benefit, we give 10 year warranty on heat ex-changer.