How to maintain compressed air treatment equipment ?

How to maintain compressed air treatment equipment ?

Maintenance of compressed air treatment equipment

1. Daily maintenance: after use every day, it is necessary to check the oil level, exhaust temperature, exhaust pressure and other aspects of the screw air compressor to see if there is any abnormality. If the oil level is too low, it is necessary to add lubricating oil in time. In addition, you also need to check whether the machine has abnormal sound.

2, regular maintenance: routine maintenance can prevent in the future, in addition to the use of a period of time to do regular maintenance is also indispensable. Regular and appropriate inspection and replacement of maintenance accessories, can be - air compressor with good quality operation. Generally, an inspection should be done after 300 hours of operation, and the frequency of inspection should be determined according to the use situation. Check accessories and cables regularly, replace immediately if damaged. In addition, keep the filter clean can avoid a lot of equipment failure, unclean filter will reduce the performance of the compressor and the service life of the compressor. Clean the filter in time, keep the machine clean and dry, not stained with oil, so as to give full play to its performance.

3, standard voltage: the safe use of air compressor is the premise of air compressor maintenance, especially for voltage, should be strictly in accordance with the voltage, frequency and rated load of air compressor calibration, compressed air post-processing equipment, so that the effect will be --, and the user will be safer for the machine. Pay attention to keep the power supply voltage consistent with the voltage identified on the nameplate of the air compressor, too high may cause personal accidents and damage to the air compressor, too low will also cause the start -- or even damage the motor.

4. Use environment: the ambient temperature of the air compressor should be kept at 5-40 ℃. The compressed air post-processing equipment in Shanghai can not be placed in a place without shelter, and do not work in a place where liquid gas and volatile gas are stored. Keep your environment clean and tidy to avoid accidents. When the air compressor is not in use, the air in the storage tank should be discharged, the sewage in the storage tank should be discharged, and stored in a dry environment.

5. Regular sewage discharge: Air compressor works in places with more dust particles for a long time, which is easy to produce dirt. Therefore, the sewage in the air compressor storage tank should be discharged clean in time. It is recommended to discharge it at least once a week, which can be determined according to the working environment.

6, habits; For example, when you go off work, you do not need to use the air compressor, and you should cut off the power supply in time. If the air compressor equipment fails, do not operate blindly. The air compressor maintenance personnel or the old master of air compressor maintenance should operate under the guidance of the operation. Before operation, the air compressor mechanical and electrical source should also be disconnected.